hitachi — REMOVE AND INSTALL PUMP DEVICE

UPPERSTRUCTURE / Pump Device 15. Remove bolts (45) (5 used). Remove bracket (32). : 19 mm 16. Remove socket bolts (52, 57) (4 used for each). Remove pipes (53, 58) from the pump device. 32 45 W1J1-02-04-045 Main Frame : 14 mm 17. Remove socket bolts (47, 49, 60) (4 used for each). Remove hoses (48, 50, 61) from the pump device. : 10 mm 18. Remove hoses (46, 51, 54, 55, 56, 59). Cap the hose and pump. Attach identification tags to the removed hoses for reassembling. : 17 mm, 19 mm, 27 mm, 36 mm, 41 mm 19. Remove all the connectors from the pump device. W2-4-5 46 47, 48 49, 50 52, 53 5 5 5 60, 61 5 57, 58 56 W1J1-02-04-001 61 60, 61 57, 58 56