hyundai — Hyundai Maintenance Manual (EN)

Unit : kgf / cm 2 7-14 13)PILOT PRIMARY PRESSURE (1) Preparation ① Keep the hydraulic oil temperature at 50±5˚C. (2) Measurement ①Select the following switch positions. ·Power mode switch : P mode ·Auto decel switch : OFF ②Measure the primary pilot pressure by the monitoring menu of the cluster. (3) Evaluation The average measured pressure should m eet the following specifications: Model Engine speed Standard Allowable limits Remarks R505LVS P mode 40±2 -