John Deere 450CLCExcavator — Take Fluid Samples

Maintenance—Every 500 Hours Clean Cab Fresh Air and Recirculating Air Filters IMPORTANT: Replace filters every 6th cleaning. Removing Cab Fresh Air Filter: 1. Tilt cab seat forward. T208066 —UN—10FEB05 2. Push both sides of filter cover (1) and lift filter cover to remove. 3. Lift fresh air filter (2) straight up to remove. Removing Cab Recirculating Air Filter: NOTE: Recirculating air filter is located under rear deck. 1. Pull clips (4) and remove outer filter (3). 2. Remove inner filter behind outer filter. T208067 —UN—10FEB05 Cleaning and Installing Filters 1. Clean filters in one of 3 ways: Tap filter on a flat surface with dirty side down. CAUTION:

Reduce compressed air to less than 196 kPa (1.96 bar) (28.4 psi) when using for cleaning purposes. Clear area of bystanders, guard against flying chips, and wear personal protection equipment including eye protection. Use compressed air opposite to the normal air flow. Wash filter in warm, soapy water. Flush filter. Allow filter to dry before using heater, defroster, or air conditioner. T208068 —UN—10FEB05 NOTE: Install fresh air filter so the stamped arrows (5) are toward the air conditioner. 2. Install filter. 3. Install filter cover (1). 4. Install recirculating air filter with the clips (4) aligned with the duct mounting holes.

1— Filter Cover 2— Fresh Air Filter 3— Recirculating Air Filter 4— Clip (2 used) 5— Stamped Arrow (2 used) T208069 —UN—10FEB05 VD76477,000018E -19-24JAN07-1/1 Take Fluid Samples See your authorized dealer for taking the following fluid samples: Hydraulic Oil JH91824,0000517 -19-27FEB09-1/1 3-8-7 060313 PN=102