Troubleshooting 21 LP69910 (12/07/2020) 3 CU FT GATOR FERTILIZER SPREADER SPN Error Description Troubleshooting Guide 6208 MD2 High VBAT Fault Motor Driver 2 voltage above 18V The module will stop operating the spreader if the system voltage rises above 18V. This is a latching fault to protect the electronics. The module must be power cycled to recover from a high voltage fault. Note that the Control Module high voltage fault is not the same as the Display Module high voltage fault. 6209 MD2 High VBAT Warning Motor Driver 2 voltage above 16V No action is necessary.
The module will continue operating the spreader with a system voltage between 16V and 18V but will stop operating the spreader if the system voltage rises above 18V. Note that the Control Module high voltage warning is not the same as the Display Module high voltage warning. 6210 MD2 Low VBAT Fault Motor Driver 2 voltage below 8V The module will stop operating the spreader if the system voltage falls below 8V. This is a latching fault to protect the electronics. The module must be power cycled to recover from a low voltage fault. Note that the Control Module low voltage fault is not the same as the Display Module low voltage fault.
6211 MD2 Low VBAT Warning Motor Driver 2 voltage below 9V No action is necessary. The module will continue operating the spreader with a system voltage between 8V and 9V but will stop operating the spreader if the system voltage falls below 8V. Note that the Control Module low voltage warning is not the same as the Display Module low voltage warning. 6212 MD2 No Communication Motor Driver 2 is not responding at power up The module will not operate if it cannot communicate with the internal motor driver at power up. Power cycle the module. If the error is still active contact Superior Tech for support.
6213 MD2 Lost Communication Motor Driver 2 has lost communication for 10 seconds The module will stop operating if it loses communication with the internal motor driver for more than 10 seconds. Power cycle the module. If the error is still active contact Superior Tech for support. 6400 Motor Driver Mismatch Version Motor Driver 1 and Motor Driver 2 have different software versions The module will not operate if the software loaded in the motor drivers does not match. Power cycle the module. If the error is still active contact Superior Tech for support.
6401 Spreader Type Memory Corruption Spreader Type stored in memory is not valid The module will not operate if the software does not load the proper spreader type from internal memory. Power cycle the module. If the error is still active contact Superior Tech for support.