EVERY 1000 HOURS SERVICE b. TRANSMISSION CASE BREATHER The type of lubricant used depends on the ambient temperature. Select according to the table “FUEL, COOLANT AND LUBRICANTS”. Refill capacity: 140 !2 Remove all mud and dirt from around the breather, then remove the breather. Put in cleaning fluid and clean the breather. 6. Pour in the specified amount of engine oil from oil filler (F). 7. After refilling, check the oil level and ensure that it is correct. (Refer to WHEN REQUIRED.) Check for oil leak at transmission case and filter. Make an oil level check before starting engine or 60 minutes or more after the engine is stopped.
If oil remains at various portions, the correct oil level cannot be measured. -91 - W-02081-A