Preparing HYDRAULIC the Tractor PRESSURE IMPORTANT: The maximum operating pressure for the planter hydraulic system is 18 961 kPa (189.6 bar) (2750 psi). Exceeding this pressure is not recommended. For complete tractor operating tractor operator's manual. instructions, refer to your B21,7PT,A CHECK TRACTOR HYDRAULIC SYSTEM -19-28JUN90 | The vacuum meter pump hydraulic system is approximately designed to be operated with closed center tractor hydraulic systems (tractors with load sensing or — depending on frame configuration, planting speed and number of rows on planter.
pressure on demand hydraulics are classified as closed center systems.) Open center tractor hydraulics are NOT compatible with system. IMPORTANT: Minimum tractor standby pressure required to operate the vacuum meter pump hydraulic system is ROCKSHAFT SELECTOR 12 411 kPa (142 bar) (1800 psi) Do not use open center tractor hydraulic system to operate vacuum pump. Permanent damage to tractor pump may result. B22,9PU,S -19-28JUN90 BO5,13PT,| -19-28JUN90 LEVER Set the rockshaft lever (A) in the “MIN” position to hitch movement. -UN-10FEB89 prevent unexpected 15-1 180790