151 SEBU7645-06 Maintenance Section Steering Column Spline (HMU Steering) - Lubricate 103589938 Steering Column Spline (HMU Steering) - Lubricate = 7 oo ph {2 SMCS Code: 4310-086-SN; 4343-086-SN |) eS a“ ‘N 8, a Illustration 206 go1477014 The metering pump is located under the front of the cab. Crushing Hazard. Connect the steering frame lock between front and rear frames before servicing the machine in the articulation area. Disconnect the lHustration 207 (1) Metering g01311462 Pump (2) Hose Coupling (3) Bolts 1. Support the metering pump (1). Loosen the four bolts (3) that hold the pump. Do not loosen the hose couplings (2).

steering frame lock and secure it in the stored po- sition before resuming operation. Failure to do so could result in serious injury or death. When you check the compact wheel loaders, perform the following step first. « Remove the plastic, cone-shaped nose in order to reach the steering valve (HMU steering). Refer to Operation and Maintenance Manual, “Steering Frame Lock” before entering the articulation joint. Note: Do not disconnect any hydraulic lines from the metering pump. Use the following steps to lubricate the splines on the steering column: Illustration 208 g01311464 (4) Splines 2. Lower the pump in order to expose the splines (4). 3. Clean the male splines on the steering column.

Clean the femaie splines in the pump. 4. Apply proper grease to the splines. Refer to Operation and Maintenance Manual, “Lubricant Viscosities” for selecting the proper grease.