Komatsu — Komatsu Operation and Maintenance Manual (EN)

. MAINTENANCE SERVICE PROCEDURE CLEAN INSIDE OF COOLING SYSTEM WARNING Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. The ratio of antifreeze to water depends on the ambient temperature, but to obtain the corrosion resistance effect, a minimum ratio of 30% by volume is necessary. When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mixing rate table given below. It is actually better to estimate a temperature about 10 ° C (18 ° F) lower when deciding the mixing rate.

Mixing rate of water and antifreeze 4 - 23 Immed iately aft er the engin e is stopp ed, the engine coo lant i s hot and the pressure inside the radiator is high. Removing the cap an d drainin g the water under this condi tion could c ause burn s. Allow the engin e to cool down , then turn the cap slowly to relea se the p ressur e. Start th e engine and fl ush th e system. When standing u p or le aving the operator's sea t, set the shift lever t o the N p osition and set the parking brake switch to the P ARKIN G position.

For det ails of s tarting the e ngine, se e "OPERATIONS, CHECKS B EFORE STARTING (PAGE 3-80)" and " STARTING ENGINE (PAGE 3-81)" in the O PERATION sect ion of the Operati on and Maintenance Manual. When t he undercover is removed, the re is d anger of to uching the fan. Never go to the front of the machine when t he engine is running. Stop the machin e on l evel ground w hen c leaning or changing the Clean th e inside of the cooling syste m, ch ange the c oolan t and replac e the c orrosion r esisto r according t o the table below.

Kind of coolant Cleaning inside of cooling system and changing coolant Replacing corrosion resistor Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours, whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant Non permanent type antifreeze containing ethylene glycol (winter, one season type) Every 6 months (spring, autume) (Drain antifreeze in spring, add antifreeze in autumn) When no using antifreeze Every 6 months or every 1000 hours, whichever come first Min.

atmospheric temperature °C Above -10 -15 -20 -25 -30 °F Above 14 5 -4 -13 -22 Amount of antifreeze Liters 26.4 30.8 35.2 39.6 44 US gal 6.97 8.14 9.30 10.46 11.63 Amount of water Liters 61.6 57.2 52.8 48.4 44 US gal 16.28 15.11 13.95 12.79 11.62