Cummins — CELECT™ COOLANT TEMPERATURE SENSOR - REMOVAL

Engine Disassembly (00-01) Fan Hub and Fan Hub Support Bracket - Removal N14 Page 0-21 Fan Hub and Fan Hub Support Bracket - Removal Remove the four capscrews that attach the fan hub to the support bracket, and remove the fan hub assembly. Remove the four capscrews that attach the fan hub sup- port (1) bracket to the cylinder block and the brace (2), and remove the fan hub support bracket. Remove the four capscrews that attach the front lifting bracket (3) to the rocker housing (4), and remove the brace (2) and the lifting bracket (3). Water Pump Belt - Removal Loosen the idler pulley shaft lock nut.

Turn the adjusting screw counterclockwise to release tension, and remove the water pump belt. CELECT™Coolant Temperature Sensor - Removal Remove the coolant temperature sensor from the ther- mostat housing.