If the lubrication system is in working order, an additional lubricating procedure of the lube unit can be started any time by depressing either the push button S84 on the rear control desk (fig. 40) or the touch 19 on the motor housing (fig. 44). MONITORING OF THE AUTOMATIC LUBRICATION SYTEM. During a lubrication procedure of the lubrication unit 2, the control light inside the push button S84 and the green LED 17 are on continuously. In case of a failure in the lube circuit (no stroke signal delivered by the proximity switch 7 about 20 minutes after begin of a lubrication procedure) both LEDs 17 and 18 and the control light inside S84 will start blinking simultaneously.

41 Possible causes are: - a plugged or kinked lubrication line, (in this case the grease will flow out of the relief valve 26, fig. 44), 2 Lubrication unit cpl. 13 Grease container 14 Electric motor 15 Grease pump S84 Control-switch inside the cab - a defective switch or defective wire, - the use of too viscous grease at very low temperatures, - not enough grease in the grease tank 13, - a problem in the 24 V electrical circuit for the motor 14. 16* Control unit 17* LED green / Pump operative, resp.

pump is lubricating 18* LED red / failure 19* Touch / reset CD* Rotary switch / Cycle Duration NS* Rotary switch / Number of strokes S84* Monitoring and Reset-switch inside the cab * With automatic system Immediately locate and remedy the cause of the trouble. ADJUSTMENT AND GREASE CONSUMPTION FOR AUTOMATIC SYSTEM The Cycle Duration can be adjusted between 0,5 and 8 hours via the rotary switch CD (Cycle Duration) after removal of the transparent protection cover. From factory, the Cycle Duration is adjusted to 1 hour.

The Number of Strokes to be carried out at main distributor for a complete lubricating procedure can be adjusted between 1 and 16 via the rotary switch NS (Number of Strokes) after removal of the transparent protection cover. From factory, the number of strokes is adjusted to 6. The factory adjusted values for cycle duration and number of strokes determine a lubricant consumption of approx. 26 cm 3 grease per lubrication cycle, it equals approx. 2,3 kg (5.1 lbs) grease every 100 working hours. 5.21 42