Caterpillar — Use of Jump Start Cables

111 WEBM1000 Operation Section (D6T LGP (OEM)) Engine Starting (Alternate Methods) Engine Starting (Alternate Methods) NOTICE When starting from another machine, make sure that the machines do not touch. This could prevent damage to engine bearings and electrical circuits. Engine Starting with Jump Start Cables Turn on (close) the battery disconnect switch prior to the boost connection to prevent damage to electrical components on the stalled machine. m WARNING Severely discharged maintenance free batteries do not fully recharge from the alternator after jump starting. The batteries must be charged to proper voltage with a battery charger.

Many batteries thought to be unusable are still rechargeable. Batteries give off flammable fumes which can explode. To avoid injury or death, do not strike a match, cause a spark, or smoke in the vicinity of a battery. This machine has a 24 volt starting system. Use only the same voltage for jump starting. Use of a welder or higher voltage damages the electrical system. m WARNING Refer to Special Instruction, Battery Test Procedure, SEHS7633, available from your Caterpillar dealer, for complete testing and charging information. Failure to properly service the batteries may cause peronal injury. Use of Jump Start Cables Prevent sparks near the batteries. They could cause vapors to explode.

Do not allow the jump start cable ends to contact each other or the machine. When the auxiliary start receptacles are not available, use the following procedure. Do not smoke when checking battery electrolyte levels. 1. Determine the failure of the engine to start. Electrolyte is an acid and can cause personal injury if it contacts skin or eyes. Reference: Refer to Special Instruction, SEHS7768 on the use of 6V-2150 Starting/Charging Analyzer. Use this procedure if the machine does not have a diagnostic connector. Always wear eye protection when starting a machine with jump start cables. Reference:

Also, refer to Systems Operation, SENR2947 “Starting and Charging Systems for Machines Equipped with Diagnostic Connector”. Improper jump start procedures can cause an explosion resulting in personal injury. Always connect the battery positive (+) to battery positive (+) and the battery negative ( ) to battery negative ( ). 2. Place the transmission control on the stalled machine in the NEUTRAL position. Engage the parking brake switch. Lower all attachments to the ground. Move all controls to the HOLD position. Jump start only with an energy source with the same voltage as the stalled machine. Turn off all lights and accessories on the stalled machine.

Otherwise, they will operate when the energy source is connected. 3. On a stalled machine, turn the start switch key to the OFF position. Turn off the accessories. 4. On a stalled machine, turn on the battery disconnect switch. 5. Move the machines together in order for the cables to reach. DO NOT ALLOW THE MACHINES TO CONTACT EACH OTHER. 6. Stop the engine on the machine that is the electrical source. When you use an auxiliary power source, turn off the charging system.