Caterpillar — Level 2 Analysis

135 WEBM1000 Maintenance Section (D6T LGP (OEM)) Cooling System Water Temperature Regulator - Replace Testing the coolant can be done at your Caterpillar dealer. Caterpillar S·O·S Coolant Analysis is the best way to monitor the condition of your coolant and your cooling system. S·O·S Coolant Analysis is a program that is based on periodic samples. See Operation and Maintenance Manual, SEBU6250, “Caterpillar Machine Fluid Recommendations”“S.O.S Coolant Analysis” for more information. Cooling System Water Temperature Regulator - Replace NOTICE Care must be taken to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting and repair of the product.

Be prepared to collect the fluid with suitable containers before opening any compartment or disassembling any component containing fluids. Perform a Coolant Analysis (Level 2) at initial 500 hours for systems that contain extended life coolant (ELC). Perform the analysis yearly after the initial 500 hours. 166 Refer to Special Publication, NENG2500 “Caterpillar Dealer Service Tool Catalog” for tools and supplies suitable to collect and contain fluids on Caterpillar products. Dispose of all fluids according to local regulations and mandates. Replace the thermostat on a regular basis per the maintenance interval schedule.

This action reduces the chance of unscheduled downtime and of problems with the cooling system. A new thermostat should be installed after the cooling system has been cleaned. Install the thermostat while the cooling system is drained or while the cooling system coolant is drained to a level that is below the thermostat housing. Illustration 166 Location of coolant sampling port 1. Park the machine on a hard, level surface. Set the engine at low idle speed. NOTICE Failure to replace the engine's thermostat on a regularly scheduled basis could cause severe engine damage. 2. Open the left side engine compartment. Remove the protective cap from the sampling valve. 3. Obtain a sample.

For additional information about coolant analysis, see Special Publication, SEBU6250 “Caterpillar Machine Fluids Recommendations” or consult your Caterpillar dealer. Note: If you are only installing a new thermostat, drain the cooling system coolant to a level that is below the thermostat housing. 1. Open the right engine compartment. 4. Replace the protective cap. Close the left side engine compartment. 167 Submit the sample for Level 2 analysis. Illustration 167