170 Maintenance Section (D6T LGP (OEM)) WEBM1000 Transmission Breather - Clean/Replace Transmission Breather - Clean/ Replace Replace Replace the transmission breather if the breather is no longer capable of cleaning. Clean 246 244 Illustration 246 1. The transmission breather is located on the bulk head bracket. Unscrew and remove transmission breather (1). 2. Install the new breather. Illustration 244 3. Close the front access door on the right side of the cab. 1. Open the front access door on the right side of the cab. Transmission Magnetic Screen - Clean 245 When you change the transmission oil, clean the magnet assembly and the screen. 247 Illustration 245 2.
The transmission breather is located on the bulk head bracket. Unscrew and remove the transmission breather. 3. Clean the breather in clean, nonflammable solvent. Illustration 247 1. Remove the bottom guard for access to the screen group. 4. Install the breather. 5. Close the front access door on the right side of the cab. 2. Remove the nuts which hold the cover to the housing. 3. Remove the screen and the magnet assembly from the housing.