Caterpillar — Containing Fluid Spillage

18 Safety Section (D6T LGP (OEM)) WEBM1000 General Hazard Information Do not smoke when you service an air conditioner. Also, do not smoke if refrigerant gas may be present. Inhaling the fumes that are released from a flame that contacts air conditioner refrigerant can cause bodily harm or death. Inhaling gas from air conditioner refrigerant through a lighted cigarette can cause bodily harm or death. Fluid Penetration Pressure can be trapped in the hydraulic circuit long after the engine has been stopped. The pressure can cause hydraulic fluid or items such as pipe plugs to escape rapidly if the pressure is not relieved correctly. Never put maintenance fluids into glass containers.

Drain all liquids into a suitable container. Do not remove any hydraulic components or parts until pressure has been relieved or personal injury may occur. Do not disassemble any hydraulic components or parts until pressure has been relieved or personal injury may occur. Refer to the Service Manual for any procedures that are required to relieve the hydraulic pressure. Obey all local regulations for the disposal of liquids. Use all cleaning solutions with care. Report all necessary repairs. Do not allow unauthorized personnel on the equipment. 16 Unless you are instructed otherwise, perform maintenance with the equipment in the servicing position.

Refer to Operation and Maintenance Manual, for the procedure for placing the equipment in the servicing position. When you perform maintenance above ground level, use appropriate devices such as ladders or man lift machines. If equipped, use the machine anchorage points and use approved fall arrest harnesses and lanyards. Pressurized Air and Water Illustration 16 Pressurized air and/or water can cause debris and/ or hot water to be blown out. The debris and/or hot water could result in personal injury. Always use a board or cardboard when you check for a leak. Leaking fluid that is under pressure can penetrate body tissue. Fluid penetration can cause serious injury and possible death.

A pin hole leak can cause severe injury. If fluid is injected into your skin, you must get treatment immediately. Seek treatment from a doctor that is familiar with this type of injury. When pressurized air and/or pressurized water is used for cleaning, wear protective clothing, protective shoes, and eye protection. Eye protection includes goggles or a protective face shield. The maximum air pressure for cleaning purposes must be reduced to 205 kPa (30 psi) when the nozzle is deadheaded and the nozzle is used with an effective chip deflector and personal protective equipment. The maximum water pressure for cleaning purposes must be below 275 kPa (40 psi).

Containing Fluid Spillage Care must be taken in order to ensure that fluids are contained during performance of inspection, maintenance, testing, adjusting, and repair of the equipment. Prepare to collect the fluid with suitable containers before opening any compartment or disassembling any component that contains fluids. Trapped Pressure Refer to Special Publication, NENG2500, “Caterpillar Dealer Service Tool Catalog” for the following items: Pressure can be trapped in a hydraulic system. Releasing trapped pressure can cause sudden machine movement or attachment movement. Use caution if you disconnect hydraulic lines or fittings. High-pressure oil that is released can cause a hose to whip.

High-pressure oil that is released can cause oil to spray. Fluid penetration can cause serious injury and possible death. Tools that are suitable for collecting fluids and equipment that is suitable for collecting fluids Tools that are suitable for containing fluids and equipment that is suitable for containing fluids Obey all local regulations for the disposal of liquids.