63 WEBM1000 Operation Section (D6T LGP (OEM)) Machine Operation Battery Disconnect Switch (25) Regeneration Switch NOTICE Never move the battery disconnect switch to the OFF position while the engine is operating. Serious damage to the electrical system could result. Force Regeneration – Press in the top of the switch for 2 seconds in order to begin regeneration. Disable Regeneration – Press in the bottom of the switch for 2 seconds in order to disable regeneration. On – Insert the key, and turn the key clockwise in order to activate the electrical system. The switch must be ON before you start the engine. Note:
The MIDDLE position of the regeneration switch is the default position for automatic regeneration. Off – Turn the key counterclockwise in order to shut off the entire electrical system. Note: You may return to normal operation at any point during a regeneration. See “Battery Disconnect Switch” in this manual for more information. Note: To re-enable automatic regeneration, cycle the engine start switch key or press and hold down the force regeneration switch for 2 seconds. If the soot level is above 15%, regeneration will begin if the machine is at low idle and is parked.
Service Hour Meter (26) Elapsed Operating Hours – Use the service hour meter to determine the service hour maintenance intervals, if equipped. Note: If the engine start switch key is cycled while the regeneration system is disabled through the disable regeneration switch, press and hold the disable regeneration switch for 2 seconds to reinitiate the disable regeneration. Diesel Particulate Filter Regeneration Soot Level Monitoring Regeneration 82 Regeneration is the removal of soot from the Diesel Particulate Filter (DPF). The Caterpillar Regeneration System (CRS) is used to regenerate the DPF. The DPF traps both soot and ash. The ash is removed through a cleaning process.
Refer to Operation and Maintenance Manual, “Diesel Particulate Filter - Clean” for more information on the service of the DPF. Illustration 82 The soot level monitor indicates the level of soot that has accumulated within the DPF. The five marks on the monitor represent a percentage of soot within the DPF. The first mark indicates 0% soot level. The second mark indicates 25% soot level. The middle mark indicates 50% soot level. The fourth mark indicates 75% soot level. The last mark indicates 100% soot level. The soot level monitor can be used to optimize DPF regenerations based upon the work cycle of your machine.
If machine conditions do not allow for an automatic regeneration, a manual regeneration should be performed before the soot level gauge indicates 100%. Regeneration Indicators Regeneration Active – This indicator will illuminate in order to show that the CRS is active. This indicator shows that elevated emission temperatures are possible. This indicator will turn off when regeneration is complete. DPF – This indicator will illuminate in order to show that a regeneration is needed. This indicator will illuminate when the soot level reaches 90%. Regeneration Disabled – This indicator will illuminate in order to show that a regeneration has been disabled.