24. SERVICE PROCEDURE EG125BS-2 (OPTION) INSPECTION If air cleaner monitor lights up, clean the air cleaner element. CLEANING AND REPLACEMENT OF OUTER CYLINDER ELEMENT 1. Loosen wing nut @ and remove the outer element. 2. Clean the inside of the body. 3. Blow dry compressed air (0.69 Mpa {7 kgf/cm?}) along the inside pleats, then along the outside pleats, then along the inside pleats again. (1) Each time the element (2) is cleaned, AE726140 remove one seal. After the outer element is cleaned six times or used for one ear, replace it.
year, rep AD726780 (3) If the dust indicator indicates red soon after the outer element is cleaned, replace the element even if it has not been cleaned six times. (4) Check the clamping nut of the inner element for looseness. If it is loosened, retighten it. NOTICE lrradiate the inside of the cleaned element with a bulb. If any hole or thin part is found, replace the element. When replacing the element, do not hit, tap it, or hit it against something. If a pleat, gasket or seal of the element is damaged, do not use that element. Keep the unused element wrapped and stored in a dry place. 4. Set the cleaned element and secure it with wing nut ©. AD053040 3-25