eng — 24.8 EVERY 2000 HOURS SERVICE

24. SERVICE PROCEDURE 24.8 EVERY 2000 HOURS SERVICE Maintenance for every 50, 250, 500 and should be carried out at the same time. 24.8.1 CLEAN ENGINE BREATHER 1000 hours service ELEMENT 1. Loosen the clamp and disconnect the hose, them, breather from the cylinder head cover. remove 2. Wash dry the whole compressed 3. breather in diesel fuel oil. Then, the it with air and install it. Check the breather hose. If any sticking to its insides, replace it. deteriorated 24.8.2 CLEAN, CHECK TURBOCHARGER Ask your Komatsu distributor to clean and charger.

24.8.3 CHECK ALTERNATOR AND oil (sludge) check STARTING is the turbo- MOTOR Since the brushes of the alternator and starting motor may be worn and grease in their bearings may have been used up, ask your Komatsu distributor for check and repair. lf the engine is started frequently, have them checked every 1000 hours. 24.8.4 CHECK ENGINE VALVE CLEARANCE, ADJUST Since special tools are required for check and adjustment of the engine valve clearance, ask your Komatsu 24.8.5 CHECK VIBRATION distributor. DAMPER Check the outside surface of the rubber for cracks or peeling. If any cracks or peeling are found, please distributor for inspection or replacement. 3-44 contact your Komatsu