eng — 16.3 OTHER TROUBLE

16. TROUBLESHOOTING 16.3.3 GENERATOR e ( e In cases ): Always contact your Komatsu of abnormalities or causes distributor when dealing with these items. which listed are not below, please contact your distributor for repairs.

Problem Main causes Voltage is not generated (voltmeter Defective voltmeter (@ Replace) e e Defective AVR Defective speed regulator (e Replace) (e Replace) e Defective voltmeter {e Replace) e e e Defective AVR Defective speed regulator Rotating speed is slow (e Replace) (e Replace) e Increase speed rated | e e e e Defective voltmeter Defective AVR Defective speed regulator Rotating speed is fast (e (e (e e Defective speed regulator {e Replace) e Imbalance of load e @ Defective breaker Defective overcurrent relay Short circuit in load circuit (e Repair or replace) (e Replace) e I!nspect does not move) Voltage is low (does not become rated voltage) Voltage is high (does not become voltage) Voltage drops excessively when is applied load Breaker cannot be switched ON 2-58 Remedy Replace) Replace) Replace) Decrease speed Adjust balance Komatsu