. ATTACHMENTS, OPTIONS HANDLING PAYLOAD METER (KOMTRAX Plus BUILT-IN TYPE) If a card-type payload meter is installed to a machine with a built-in KOMTRAX Plus type payload meter, the KOMTRAX Plus type payload meter will not work. 6 - 35 PAYLOAD (CYCLE DATA ITEM) re recorded as data, apply to the haul payload in the applicable cycle. of confirming the haul payload. The payload measurements, which a re recorded as data, apply to the haul payload in the ap There are the following two methods 1: At the dumping point, record the payl oad when the dump lever is moved from FLOAT to any p osition other than FLOAT. 2:

Process the data sampled when trav eling from the loading point to the dumping point, then c onfirm and record the haul payload when dumping. When the machine is shipped from the f actory, the same Method 1 is used as for the conventional card type payload meter (PLM II). The method for processing and conf angle. If you wish to change the method of c the change. irming the payload in Step 2 above is useful if the dumping point is at an If you wish to change the method of c onfirming the haul payload, please ask your Komatsu dist ributor to carry out the change. SERVICE FUNCTIONS The following functions are available, b ut for normal use, there is no need to make any change.

If it is necessary to change the setting, please consult yo ur Komatsu distributor. cognize completion of loading 1. Setting travel distance needed to re The payload meter is set to judge t 11 in) continuously from the loading point, the system will not judge that In cases where the loading point an setting for the travel distance neede 2. Selecting method of confirming rec Use this function to change the sele 1) At the dumping point, record the than FLOAT. 2) Process the data sampled whe record the haul payload when d . Setting travel distance needed to re hat the loading is completed when the machine has trav eled 160 m (524 ft point.

If the dumping point is within 160 m (524 ft 11 in ) from the loading dumping has taken place, so the cycle data at that point will be incomplete. d the dumping point are extremely close, use this functio n to change to the d to recognize the completion of loading. orded payload ction of the method below to confirm the haul payload. payload when the dump lever is moved from FLOAT to any position other n traveling from the loading point to the dumping point, then confirm and umping. OTHERS If it is necessary to correct the dat distributor.

a or time during the download operation, please consult your Komatsu If the payload and external display la mp display is different, or there is some error in the directo ry where the data is downloaded by the special softwar e, there may be a mistake in the setting for the machine In such a case, please consult your Use a serial communication port (RS For computers without an RS232C po rt, it may be possible to use a third party USB-RS232C co nversion adapter. (Part for operation check: IO DATA U SB-RSAQ2) However, this does not guarantee the operation. In addition, the download software supports C OM1 and COM2, so check which port it can be connec ted to.

of communicating with the external equipment prepared by the customer. omatsu distributor. The payload meter has the function of communicating with the external equipment prepared For details, please check with your K However, communications are carrie d out using the RS232C port for downloading,so in this ca se, it is impossible to download the data from the inside or outside of the cab.