Kaiyi DX225LCA — Kaiyi DX225LCA — спецификация (EN)

SP001727 Page 29 Electrical System MODE SELECTOR SWITCH Power Mode / Switch Operation Mode Output Check (Operation mode display LED) e-EPOS Output Electromagnetic Proportional Pressure Reducing Valve (E.P.P.R Valve) Current (mA) Swing Priority Solenoid Valve 7-Segment Display Power Mode Power Mode ON No-load: 200 ±20mA Load: Variable output (Max. current: 600 ±20mA) - 9 x Standard Mode OFF No-load: 300 ±20mA Load: Variable output (Max. current: 600 ±60mA) - 7 x NOTE: When the engine speed is below 1,000 rpm, the output current of E.P.P.R valve is fixed to be 600 ±60mA. Auto Idle Switch Operation Mode Output Check (Operation mode display LED) Auto Idle Activation ON Cancellation OFF