EXPLANATION OF COMPONENTS OPERATION PRECAUTIONS WHEN USING AIR CONDITIONER Carry out ventilation from time to time when using the cooler. G If you smoke when the cooler is on, the smoke may start to hurt your eyes, so turn the lever to FRESH to remove the smoke while continuing the cooling. G When running the air conditioner for a long time, turn the lever to the FRESH position once an hour to carry out ventilation and cooling. G When the cooler is on, set the temperature so that it feels slightly cool when entering the cab (5 - 6°C lower than the outside temperature).
This temperature difference is considered to the most suitable for your health, so always be careful to adjust the temperature properly. Be careful not to make the temperature in the cab too low. G If the vents (left and right)in the middle of the dashboard are turned so that cold air plays directly on the cab door glass, moisture may condense on the outside of the cab door glass and reduce the visibility. (This occurs particularly in high temperatures.) If this happens, turn the vent shutter selector lever to stop the air going directly to the glass and direct it upward.
Direction of vents when cooling INSPECTION DURING OFF-SEASON Even during the off-season, run the compressor at low speed for several minutes once a week to prevent the loss of the oil film at the lubricated parts of the compressor. (Run the engine at low speed and set the temperature con- trol lever at the central position.) REMARK When the ambient temperature is low, if the compressor is suddenly run at high speed, it may cause failure of the compressor. Note that the system is set so that the compressor will not run when the cooler switch is turned on if the ambient temperature is less than 2 - 6.5°C. PROCEDURE FOR REPLACING RECEIVER Replace the receiver once every two years.
After replacing the receiver, add compressor oil. Turn the old receiver at an angle and measure the oil remaining inside the receiver, then add the same amount of oil (Denso Oil 6) to fill the new receiver. REMARK G Depending on the condition of use, the replacement interval may be shorter. G If the receiver is used when the desiccant has exceeded the water absorption limit, the refrigerant ircuit may become clogged and cause failure of the compressor. Precautions when replacing receiver G If the receiver is left for more than 15 minutes with the blind cover removed, the moisture in the air will be absorbed, and this will reduce the life of the desiccant.
If you remove the blind cover, connect the piping quickly, evacuate the system and fill with refrigerant. G When removing the refrigerant from the refrigerant ircuit, release it gradually from the low pressure side to pre- vent oil from flowing out. 3-56