K ENWORTH T680 MIRRORS - SERVICE MANUAL 6.4. ELECTRICAL CONNECTOR 6.4.1. Wire pin layout The wire pin layout does not change for Left Hand, Right Hand, Manual nor Remote Mirrors. Pin layout is the same for all mirrors. See the table below for the wire pin layout. - Add plug Note: The 2 black heater wires have no polarity and can be inserted vice versa at either #1 or #8. Plug all unused cavities with a sealing plug. The electrical wire diagram of the left-hand mirror system is shown below. Except for the OAT sensor (green and blue wires) the diagram is the same for the right hand mirror. Copyright © Lang Mekra North America 2014 Page 17 of 28 Revised:
03/2014 Left Hand Right Hand # Color (Function) Remote Manual Remote Manual 1 Black (Heater-) X X X X 2 White (Act Grd) X - X - 3 Yellow(Act L/R) X - X - 4 Grey(Act U/D) X - X - 5 Green (OAT-) X X - - 6 Blue (OAT+) X X - - 7 - [Sealing Plug] - - - - 8 Black (Heater+) X X X X Sealing Plug