daewoo — daewoo Diesel Engine Manual (EN)

D1146/D1146TI/DE08TIS MAINTENANCE MANUAL z Install the special tool (compression gauge adapter) at the nozzle holder hole, and connect the compression pressure gauge there. Condition : Water temperature 20 ° C, Engine rotation 200rpm (10 rotations) G1068 2.1.10. Injection nozzle z Install a nozzle on the nozzle tester. z If the inspected injection pressure is less than the specified value, adjust using the adjusting shims. z Check the atomizing state and replace it if abnormal. 2.1.11. Fuel injection pump z Check the housing crack, damage etc. and replace it if abnormal. 19 Printed in Jan.

2001 PS-MMA0415-E1A Standard value 28kg/cm2 over Limit value 24kg/cm2 Difference between each cylinder Within ± 10 % Engine Model D1146 D1146TI DE08TIS Opening pressure 210 kg/cm2 214 kg/cm2 1st : 160 kg/cm2 2nd : 220 kg/cm2