Mitsubishi Heavy Industries — FUEL SYSTEM

6-2 Inspection (1) Check valve Inspect the seating faces of the check valve for wear, and replace parts found in abnormally or excessively worn condition. (2) Tappet wear Mike the tappet and tappet hole to determine their diametral wear. Replacement is necessary if the amount of wear noted in comparison with the standard diameter is 0.1 mm (0.004 in.) otmore. Specifications Unit: mm (in.) The overall play of tappet roller pin, involving the pin hole and roller, is prescribed to be not greater than 0.3 mm (0.012 in.). If this limit is exceeded, the whole tappet sub-assembly must be replaced. Replace the roller if its diameter has worn down to the service limit. Specifications Unit:

mm (in.) (3) Pump housing damage Inspect the housing for cracks, broken screw threads and other types of damage and repair or replace it as necessary. (4) Priming pump wear Inspect the piston and cylinder for scratch marks, wear and rusting. Check the seating faces of its valve for wear. An excessively worn or damaged seating face must be corrected by replacement. -66 - Item Standard Service limit Tappet OD 20 (0.78) 0.1 (0.004) Tappet hole ID 20 (0.78) 0.1 (0.004) Item Standard Service limit Tappet roller OD +0 15 -0.027 (0.591 j.00106) -0.075 (-0.00295)