(c) Armature inspection 7-3 Battery Alternatively check four wire leads of the armature coil for continuity with a tester as shown: Check the electrolyte level in the battery cells, making sure that it is 10 mm (5/16 in.) above cell plates. Check the specific gravity of electrolyte. If it is below 1.260 at 20°C (68°F), prepare an electrolyte of 1.260 specific gravity and add it to the battery. A specific gravity below 1.190 means that the battery is half discharged; in such a case recharge the battery. Checking armature If there is no continuity between the wire leads, it is an indication that the armature has open cir- cuit. Replace the armature with a new one.
Then, check the armature for continuity between the wire lead and core. If there is continuity, it is an indication that there is a grounded circuit between the wire and core. In this case, too, the armature should be replaced. Checking electrolyte specific gravity 7 -4 Glow plugs Connect the positive (+) lead to the portion A of the plug with the portion B grounded to see if the plug glows red. The plug is in good condition if it glows red. (d) Brushes Any brush which is worn beyond the service limit should be replaced with a new one. Wear limit line Checking glow plug J20198 -86-