5-111.bk Page 101 Monday, July 10, 2006 2:26 PM CMCAC Pressure Test 5. When plugs are secured, attach an air line (fitted to a pressure regulator and gauge) to the air line adapter in the core outlet opening. Refer to Figure 97. 1. Remove the air ducting from core. 2. Plug the core inlet opening. 6. Pressurize the system to 30 psi (207 kPa). 7. Shut off the air source. Pressure should not drop more than 5 psi (35 kPa) within 15 seconds. Repair or replace the core if pressure drop exceeds specification. 3. Insert a plug with an air line adapter in the core outlet opening. 8. Carefully release pressure from the system.
Charged air cooler pressure fixture J 41473 can be used on coolers with the flange connections. 9. After repairing or replacing the core, reconnect ducting. Tighten clamp nuts until clamp spring is fully compressed. 4. Connect a safety chain or cable to both plugs. When the spring is fully compressed, the torque applied on the nut is generally between 40–55 lb-in (4.5–6.2 N m). Stand clear of the plug area when system is pressurized. 97 Figure 97 — CMCAC Pressure Test Page 101 TROUBLESHOOTING 1. Core Inlet 2. Core Outlet 3. Plug (Part of J 41473) 4. Safety Chain 5. Air Pressure Regulator and Gauge (J 41473)