5-111.bk Page 195 Monday, July 10, 2006 2:26 PM INSTALLATION 194 Apply an appropriate Teflon ® thread sealant to the threads and install the plug. Tighten the plug to specification. Refer to the torque chart in the SPECIFICATIONS section. New plugs may already have a sealer applied to the threads. Applying a Teflon ® sealer to the threads will not adversely affect the precoating. H-Ring Replacement [213 LD] H-rings are placed in the lifter bores to prevent the lifters from turning, and performing the same function as the roller tappet guide pins used with electronic unit pumps.
The H-rings have an interference fit with the lifter bores in which they are installed and, under normal circumstances, are never removed. If an unusual failure situation results in an H-ring being dislodged, it can be reinstalled or replaced with a new part, as required, using the following procedure: Figure 194 — H-Ring Removal 1. Remove the affected H-ring, using remover tool J 42426 in combination with slide hammer J 6125-1B. Refer to Figure 194. Page 195 REPAIR INSTRUCTIONS, PART 1