DD PLATFORM APPLICATION AND INSTALLATION MANUAL Figure 6-5 Static Pressure Tap The instrumentation should be placed perpendicular to the plane of the bend where measurement on a bend is unavoidable. 6.4.2 MEASUREMENT OF TEMPERATURE DROP FROM TURBOCHARGER TO ATD INLET The temperature of the exhaust gas exiting the turbocharger must be maintained as high as possible in order to maximize the performance of the DOC and to aid in the regeneration process of the DPF. Two temperature measurements are required to validate this criterion. The first measurement should be taken in the exhaust pipe as close as is practical to the outlet of the HC Doser elbow.