DD PLATFORM APPLICATION AND INSTALLATION MANUAL 7.7.1 MOUNTING ZONES There are designated areas, or mounting zones, on the ATD that are reinforced. The mounting zone areas are the only locations where the ATD can be held. If the ATD is held outside the mounting zones the outer skin of the ATD could indent the outer skin of the ATD potentially causing a hole. Please refer to the ATD drawing to get the dimensions of the mounting zones and torque specifications for the specific ATD being installed. 7.7.2 BENDING MOMENT FOR INLETS AND OUTLETS Under no circumstances should the inlets and outlets of the ATD support the weight exhaust plumbing going into and out of the ATD.

The exception to this rule is for vertical ATDs only. The outlet is designed to withstand up to a particular amount of unsupported topstack mass. Please refer to the ATD drawing to get the inlet and outlet bending moment restrictions for the specific ATD being installed. Anything expected to exceed these limitations needs to have additional brackets to support the topstack. To reduce the loads into the inlet and outlet of the ATD, stiff brackets are to be used to mount the ATD to reduce low frequency wave vibration. Suggested frequency? A flexible section of piping is required between the turbocharger turbine outlet and the inlet to the ATD.

A flexible section is also required on the outlet side of the ATD. These flex sections are necessary in order to minimize the amount of engine and exhaust system vibration that is transmitted to the exhaust system and the ATD. Premature failure of the turbocharger, manifold, piping, ATD or joints caused by engine vibration may be prevented by including flexible joints or fittings. A flexible joint allows for thermal expansion and facilitates alignment of the engine with the exhaust system piping. Please refer to the Exhaust System portion of the ATD. Note that a minimum separation distance of 6mm is needed to pull the DPF portion of the ATD out of the ATD assembly.

Aftertreatment Components group is going to perform the “lower over pass” crash test to see what happens with the rain trap and what fails. The DPF portion should not be damaged or else this will be an expensive failure. 7.7.3 DRAINAGE Vertical ATDs have a rain trap incorporated into the top to aid in the prevention of water from entering the exhaust system. This is not 100% efficient. Horizontal ATDs have a small drain hole on the outlet of the ATD to aid in the prevention of water entering the exhaust system. Exhaust systems must be designed accordingly to prevent water from entering them and getting back to the engine. Please refer to the exhaust system portion of the ATD.

These designs are secondary measures for water prevention. Should water pass through the exhaust system into the engine, catastrophic engine failure can occur. Horizontal ATDs need to be oriented such that the drain hole is in the correct orientation when mounted as to aid in water drainage. There may be some sort of trap volume that needs to be required. V = 1.7gal for 4 in. V = 2.67gal for 5 in. All information subject to change without notice. 7-13 DDC-SVC-MAN-0073 Copyright © 2009 DETROIT DIESEL CORPORATION