Kaiyi — Installation

AIR CONDITIONING 1B-33 Removal Preparation: Disconnect the battery ground cable. Discharge and recover refrigerant. 1. Evaporator Assembly Refer to “EVAPORATOR ASSEMBLY” removal procedure in this section. 2. Amplifier & Thermistor Pull out the grommet from the upper case to re- move the thermostat. 3. Upper Case Remove the sensor fixing clip. Separate the upper and lower case. Slit the case parting face with a knife since the lin- ing is separated. 4. Insulator and Cover 5. Evaporator Core Pull up the core from the lower case. 6. Expansion Valve Take off two installation bolts and subsequently re- move pipe assembly and expansion valve sequen- tially.

N1A0194E Installation To install, follow the removal steps in the reverse order, noting the following points: 1. Tighten the expansion valve to the specified torque. Tighten: Installation bolts to 5 N m (0.5 kg m/3.7 lb ft) 2. O-rings cannot be reused. Always replace new ones. 3. Be sure to apply new specified compressor oil to the O-rings when connecting lines. 4. To install a new evaporator core, add 50cc (1.4 Imp. fl oz) of new specified compressor oil to a new core. 5. Apply an adhesive to parting face of lining when assembling evaporator assembly. 6. Install the amplifier & thermistor sensor (2) surely to the evaporator core specified position with the clip (1) where it was before.