Doosan DX220A DX225LCA — Starting Engine With a Booster Cable

6. After engine has started, release key. Key will return to the "I" (ON) position (Figure 10). 7. After the engine starts, check all operating indicators to make sure that all engine systems (oil pressure, coolant, etc.) are in the normal operating range. If any problems are noticed, shut down engine. 8. Follow "Hydraulic System Warm-up" procedures in this section. (See page 3-9) Starting Engine With a Booster Cable WARNING 1. An explosive gas is produced while batteries are in use or being charged. Keep flames or sparks away from the battery area. 2. Charge batteries in a well ventilated area. 3. Always wear eye protection when starting a machine with jumper cables. HAOA440L Figure 11 4.

Improper jump starting procedures can cause an explosion resulting in personal injury. 5. Jump start vehicles on dry ground or concrete. Do not jump start the machine on a steel floor, because the floor is always grounded. 6. When starting from another machine, make sure the machines do not touch. 7. Always connect the auxiliary battery positive (+) terminal too depleted battery positive (+) terminal first. Then connect auxiliary battery negative (-) terminal to the frame of the depleted battery machine second. 8. Connect positive cable first when installing cables and disconnect the negative cable first when removing. IMPORTANT The machine has a 24V (-) negative ground electrical system.

Use the same capacity 24V booster batteries when jump starting engine. If the batteries are drained during starting procedures, jump start engine using auxiliary or booster batteries according to the following procedure; OP001761 3-7 Operation