Hydraulic Breaker Operation NOTE: Hydraulic pressure and flow settings may need to be changed. Refer to the Maintenance Section of this manual for further information. 1. Make sure to read and understand the breaker user's manual. 2. Inspect all mechanical and hydraulic connections. 3. Do not use the breaker as a hammer. See Figure 73. Do not drop breaker from extreme heights. The breaker is relatively heavy and drops fast. Do not drop breaker from extreme heights or damage to upper structure may result. FG000188 Figure 73 4. Do not operate the breaker with the boom or arm cylinders fully extended (bottomed out). See Figure 74.
Leave over 100 mm (4 in) of clearance between rod end of cylinder and cylinder head. This will help prevent damage to cylinders during breaker operation. Figure 74 5. Do not use the breaker if the hydraulic hoses vibrate excessively. See Figure 75. Check the breaker's hydraulic accumulator (1) for damage and repair as required. If excavator is operated under this condition, structural and hydraulic components can be damaged. 1 Figure 75 FG000215 OP001761 3-35 Operation FG000191