Doosan DX220A DX225LCA — Check Fuel Level

6. If oil level is above the "H" mark drain oil. A. Shut down engine and wait for the hydraulic oil to cool down. B. Drain the excess oil from drain plug (Figure 19) at the bottom of the tank into a suitable container, using a hose at the port (plug). NOTE: Dispose of drained fluids according to local regulations. FG013200 Figure 19 Check for Leaks in Hydraulic System 1. Perform a daily walk-around inspection to make sure that hoses, piping, fittings, cylinders and hydraulic motors are not showing any signs of leakage. If any is noted, determine the source of the leak and repair. Check Fuel Level 1 WARNING Use extreme safety precautions while refueling to prevent explosions or fire.

Immediately clean up any split fuel. 2 FG000130 1. At end of each work day, fill fuel tank. Add fuel through fuel fill tube (1, Figure 20). When working at a temperature of 0°C (32°F) or higher, use ASTM No. 2-D or its equivalent. At temperatures below 0°C (32°F) use ASTM No. 1-D or its equivalent. Figure 20 2. Make sure that fuel fill hose is grounded to the excavator before fueling begins. 3. Check the amount of fuel in the tank by observing the fuel tank sight gauge (2, Figure 20). NOTE: See “Fluid Capacities” on page 4-8. for capacity. 4. The excavator may be equipped with the optional battery operated fuel fill pump. The pump assembly is in the hydraulic pump compartment.

Put the suction hose of the pump into the fuel resupply tank. Turn the switch in the pump compartment "ON," and the fuel will be pumped into the excavator fuel tank. NOTE: See “Fuel Transfer Pump (Optional)” on page 4-74, for further information. 5. Do not overfill the tank. OP001762 Inspection, Maintenance and Adjustment 4-16