Doosan DX220A DX225LCA — Change Pilot Filter

Change Pilot Filter NOTE: Change pilot filter after first 250 hours of operation or rebuild, and every 1,000 hours thereafter. 02/05 [MO] 11:30 NOTE: If pilot filter clogged warning light (Figure 73) on instrument panel comes "ON" the pilot filter must be serviced. E F C H E/G SPEED Figure 73 FG000763 WARNING The hydraulic oil will be hot after normal machine operation. Allow the system to cool down before changing pilot filter. 1. Park machine on firm, level ground. Lower the front attachment to the ground and shut down engine. 2. Lift the breather cap (1, Figure 71) slightly to release the internal pressure. Figure 74 3. Locate pilot system filter assembly. See Figure 74. 4.

Unscrew canister (5, Figure 75) and remove O-ring (3) and filter cartridge (4). NOTE: The canister will be filled with oil. Use caution when removing this assembly. 2 1 3 5. Insert a new filter cartridge and O-ring. Apply a small amount of oil around the entire O-ring and install the canister assembly onto the filter head (1, Figure 75). 4 NOTE: Used filter should always be disposed of according to local regulations. 5 6. After changing pilot filter, vent air from pump and check level of hydraulic oil tank. FG000323 Figure 75 OP001762 4-43 Inspection, Maintenance and Adjustment F G005881