OP001762 Inspection, Maintenance and Adjustment 4-46 Check Air Conditioner Refrigerant WARNING Mixing of tobacco smoke and freon is deadly. Do not smoke while servicing or recharging air-conditioning system. 1. Run engine at about 1800 rpm. Operate for a minimum of FG00644 ten minutes to stabilize the system. Figure 81 2. Press the "HI" fan speed switch to set maximum air flow. 3. Put the temperature control switch in maximum cooling position. 4. Press the "Internal Air Circulation" switch. 5. Compare the flow of bubbles in the sight glass of receiver dryer with the drawings in the following table.
CAUTION Overfilling refrigerant may cause dangerous high-pressure and poor cooling action; and low refrigerant level may cause compressor damage. Always maintain refrigerant at normal level. Amount of Appearance of the Sight Glass Solutions Refrigerant Almost clear. Normal Any bubbles disappear. Charge or withdraw the system with the correct amount of High No bubbles are seen. HFC-134a refrigerant. Low A flow of bubbles is visible. Check and Adjust Engine ** Contact your nearest DOOSAN dealer. Engine dealer for checking and adjusting the following items: • Engine Compression Pressure. • Injection Pressure. • Injection Timing.
FG00644 3 Amount of Refrigerant Appearance of the Sight Glass Solutions Normal Almost clear. Any bubbles disappear. High Char with No bubbles are seen. HFC- A flow of bubbles is visible. ge or withdraw the system the correct amount of 134a refrigerant. Low