SECTION 3 MACHINE TRANSPORT AND STORAGE Page 6 3.4. MACHINE STORAGE NOX RUST VCI # 105 OIL DAUBERT CHEMICAL COMPANY 1200 JORIES BLVD OAK BROOK, ILLINOIS 60521, USA or from Authorized Distributor of Construction Equipment WARNING! Rust inhibitors are volatile and flammable. Prepare machine in a well ventilated place. Keep away from open flame or sparks DO NOT SMOKE. Store container in a secure, cool, well ventilated place. WARNING! Due to the volatile nature of "VCI", irritation of eyes and skin may occur. Prolonged exposure to the vapors or oil should be avoided. 11. Vent the fuel system. Refer to “FUEL SYSTEM” in Section 4. 12.
Start the engine and run at 1400 – 1600 RPM, no load for approximately 4 minutes and stop the engine. 13. Lubricate all points of the machine as outlined in the “SERVICE GUIDE”. NOTE: Be sure to oil or grease all linkage connections, joints, nuts, pins, shafts, and bushings not covered in the “SERVICE GUIDE”. 14. Drain the crankcase oil from the engine, replace the lubricating oil filters and refill with the specified oil. Refer to "ENGINE". 15. Add 15 ml of "VCI" for each liter of engine oil capacity to the crankcase. (Example: if the total crankcase capacity is 10 liters, add 150 ml of VCI to the crankcase). WARNING!
Due to the volatile nature of "VCI", irritation of eyes and skin may occur. Avoid prolonged exposure to the vapors or oil. 16. Start the engine and run at 1400 – 1600 RPM, no load, for approximately 30 seconds and stop the engine. 17. Remove the air intake cap. 18. Seal all external openings (i.e. engine exhaust outlet, crankcase and hydraulic breathers, fuel vent line, etc.) with waterproof tape wide enough to cover the opening. NOTE: When sealing with tape, be sure to extend tape approximately 25 mm beyond opening to insure a good seal. 19.
Pour 120 ml of "VCI" into the intake manifold to provide sufficient corrosion protection for the area between the top of the piston and the bottom of the cylinder head. 20. Add 350 ml of VCI to the hydraulic reservoir. 21. Remove the batteries and store them in a cool, clean, dry, well ventilated place away from areas storing or dispensing fuel and oil, not near any heat source and preferably where the temperature range is between 0°C to +21°C.Be sure the batteries are fully charged. NOTE: Do not leave batteries on a concrete floor or in freezing temperatures IMPORTANT:
If the machine is stored with dry-charged batteries or no batteries, the alternator output lead must be disconnected and insulated. Failure to do so may result in permanent damage to the alternator. Connect the output lead only after the batteries have been activated with electrolyte. Refer to "ELECTRICAL SYSTEM". TD-20H DRESSTA