STRUCTURE, FUNCTION, & MAINTENANCE STANDARD MULTI MONITOR SYSTEM SELECT MODE FUNCTION This is used when setting the flow in each working mode. It is possible to make the setting when genuine attachment piping is installed and the initial value set- ting function on the service menu has been used to set to ATTACHMENT INSTALLED. It is possible to check on the working mode monitor if this function can be set. B mode [B] + flow symbol METHOD OF USE Carry out the setting on the normal screen 1. A mode, E mode 1) Press select switch (1) on the monitor to move to the adjustment screen. 2) Press control switch (2) to select the flow level.
3) After completing the level selection, press input confirmation switch (3). The selection flow level is confirmed and the screen moves to the normal screen. From the moment that the flow level is selected, the content of the selection is reflected for the attachment flow. Before the input confirmation switch is pressed, the flow levelis not confirmed, so press return switch (4) to return to the nor- mal screen. This function can be used to return to the previously set flow. The relationship between the set flow level and the flow value is as shown in the table on the right.
Flow level Flow (L/min.) Remarks 8 430 Default 7 350 6 250 5 170 4 140 3 115 2 90 1 30 10-206 PC210/240-7K Working mode Monitor display A mode [A] + crusher symbol E mode [E] + crusher symbol Control switch Actuation Flow level bar graph extends to the right Flow level bar graph retracts to the left