STRUCTURE, FUNCTION, & MAINTENANCE STANDARD MULTI MONITOR SYSTEM MAINTENANCE FUNCTION When the maintenance time for replacement, inspection, or filling has approached for the 10 maintenance items, press maintenance switch (1) and the caution display (yel- low or red) appears on the monitor display for 30 seconds after the key is turned ON to remind the operator to carry out lubrication maintenance. Maintenance items Option, so not set The above replacement intervals are set for each item, and the time remaining to maintenance is reduced as the machine is operated. The content of the caution display differs according to the ramaining time. The relationship is as shown in the table below.
PC210/240-7K 10-209 No. Item Replacement inter- val (hours) 01 Engine oil 500 02 Engine oil filter 500 03 Fuel filter 500 04 Hydraulic filter 1000 05 Hydraulic tank breather 500 06 Corrosion resistor ❈ (1000) 07 Damper case oil 1000 08 Final case oil 2000 09 Machinery case oil 1000 10 Hydraulic oil 5000 Display Condition None Remaining time for mainte- nance for all items is more than 30 hours Notice display (black symbol displayed on yellow back- ground) There is one or more items with less than 30 hours remaining time for mainte- nance Warning display (wiper sym- bol displayed on red back- ground) There is one or more items with less than 0 hours remaining time for mainte- nance