Komatsu — mULTI MONITOR SYSTEM

STRUCTURE, FUNCTION, & MAINTENANCE STANDARD MULTI MONITOR SYSTEM SERVICE METER CHECK FUNCTION When the starting switch is at the OFF position, keep return switch (1) and control switch (2) of the monitor pressed at the same time, and the service meter is shown on the display. This display is shown only while the two switches are being pressed. When the switches are released, the display goes out. Note that it takes 3 - 5 seconds after the switches are pressed for the service meter display to appear.

DISPLAY LCD CHECK FUNCTION On the password input screen or on the normal screen, if monitor return switch (1) and working mode (A) switch are kept pressed at the same time, all the LCD display will light up and the whole screen will become white, so the display can be checked. If any part of the display is black, the LCD is broken. 08943 10-214 PC210/240-7K