TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS 20-4 PC210/240-7K Applicable model PC210, 210LC,210NLC-7K PC240LC, 240NLC-7K Cate-gory Item Measurement Condition Unit Standard value Permissible value Standard value Permissible value Hydraulic pressure Unload pressure • Hydraulic oil temperature: Within operation range • Engine at high idling • Working mode: A mode • Hydraulic pump output pressure with all control levers in NEU- TRAL position MPa {kg/ cm2} 3.9±1.0 {40±10} 3.9±1.0 {40±10} 3.9±1.0 {40±10} 3.9±1.0 {40±10} Boom • Hydraulic oil temperature: Within operation range • Engine at high idling • Working mode:
A mode • Hydraulic pump output pressure with all measurement circuits relieved • Values inside parenthesis: Hydraulic oil pressure with one- touch power max. switch in ON mode (reference only) 34.8±1.0 {335±10} 37.3±1.0 {380±10} 33.3–36.8 {340–375} 36.3–39.2 {370–400} 34.8±1.0 {335±10} 37.3±1.0 {380±10} 33.3–36.8 {340–375} 36.3–39.2 {370–400} Arm Bucket Swing 30.9±1.5 {315±15} 28.9–32.9 {295–335} 30.9±1.5 {315±15} 28.9–32.9 {295–335} Travel 38.2±1.0 {390±10} 37.3–40.2 {380–410} 38.7±1.0 {395±10} 37.3–40.2 {380–410} Control circuit source pressure • Hydraulic oil temperature:
Within operation range • Engine running at high idling • Self-reducing pressure valve out- put pressure with all control levers in NEUTRAL position 3.23±0.2 {33±2} 2.84–3.43 {29–35} 3.23±0.2 {33±2} 2.84–3.43 {29–35} Self- reducing pressure valve • Hydraulic oil tem- perature: Within operation range • Engine at high idling • Working mode: A mode • Traveling speed: Hi • Hydraulic oil pump pressure - LS pres- sure When all control levers in NEUTRAL position 3.9±1.0 {40±10} 3.9±1.0 {40±10} 3.9±1.0 {40±10} 3.9±1.0 {40±10} When traveling at half stroke (without load) 2.2±0.1 {22±1} 2.2±0.1 {22±1} 2.2±0.1 {22±1} 2.2±0.1 {22±1}