Komatsu — STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS 20-8 PC210/240-7K Applicable model PC210, PC210LC, 210NLC-7K PC240LC, 240NLC-7K Cate-gory Item Measurement Condition Unit Standard value Permissible value Standard value Permissible value Travel Travel deviation 45 mm Max. 150 Max. 250 Max. 150 Max. 250 BKP00105 • Hydraulic oil temperature: Within operation range • Engine at high idling • Working mode: A mode • Travel speed: Lo • Solid and flat ground • Swerving amount while traveling 20 m (X) after ini- tial 10 m trial run 20m 10m BKP001 10m Hydraulic drift of travel 12˚ BKP00108 mm 0 0 0 0 • Hydraulic oil temperature:

Within operation range • Engine stopped • Parking machine on slope of 12 degrees with sprocket facing upslope • Sliding distance for 5 min- utes Leakage of travel motor • Hydraulic oil temperature: Within operation range • Engine at high idling • Traveling with sprocket locked • Oil leakage amount for one minute with traveling in relief condition ¶/min 13.6 27.2 13.6 27.2