Komatsu — iNSPECTION AND ADJUSTMENT OF PUMP PC CONTROL CIRCUIT OIL PRESSURE(PC210/LC/NLC)

TESTING AND ADJUSTING INSPECTION AND ADJUSTMENT OF PUMP PC CONTROL CIRCUIT OIL PRESSURE 4) Measure the hydraulic oil pressure with all the control levers kept in the NEUTRAL position and the engine running at high idling and at low idling. If PC-EPC valve output pressure chang- es to the following values, it is judged normal. 1. Loosen lock nut (8) and make adjustment, turn- ing adjusting screw (9). If the holder is turned to the right, the pump absorption torque rises. If the holder is turned to the left, the pump absorption torque falls. The adjustable range with the adjusting screw is as shown below. Left turn: Less than 1 turn Right turn:

Less than 1/2 turn (less than 180 degrees) 3 Lock nut: 27.50–34.3Nm{2.8–3.5kgm} Adjustment If any of the phenomena mentioned below oc- curs and PC valve malfunctioning is suspected, adjust PC valves (6) and (7) in the following man- ner. As workload increases, the engine rpm sharply drops. While the engine rpm is normal, the work equipment moves slowly. 2. Confirm that the PC valve output pressure (servo piston inlet pressure) is normal after the adjustment, following the measurement steps explained earlier. 20-126 PC210/240-7K Engine speed Control lever Hydraulic oil pressure Low idling Neutral 2.9 MPa {30 kg/cm2} High idling 0{0}