TESTING AND ADJUSTING MEASUREMENT OF PPC VALVE OUTPUT PRESSURE MEASUREMENT OF PPC VALVE OUTPUT PRESSURE PPC valve output pressure measurement tools 2. Fit fitting of hydraulic tester M and connect oil pressure gauge . Use an oil pressure gauge with the capacity of 5.9 MPa{60 kg/cm 2 }. Measure PPC valve output pressure after con- firming that control circuit original pressure is normal. 1. Remove PPC oil pressure switches (1) through (12) in the hydraulic circuits to be measured. 3. Start the engine and keep it running until the hydraulic oil temperature rises to the operating range.
Oil pressure switches (1) through (8) are in- stalled in the PPC relay block, and (9) and (10) are installed at the rear of operator's cab. 4. Measure the pressure when the engine is run- ning at high idling and the control lever of the cir- cuit to be measured is kept in the NEUTRAL position and at the full stroke. If PPC valve output pressure is at the level shown below, it is judged normal. 5. Detach all the measurement tools, and make sure that the machine is back to normal condi- tion. 20-138 PC210/240-7K Mark Part No. Part Name M 799-101-5002 Hydraulic Tester 790-261-1203 Digital Type Hydraulic Tester No. Circuit to be measured No.
Circuit to be measured 1 Boom, RAISE 7 Swing, left 2 Boom, LOWER 8 Swing, right 3 Arm, DIGGING 9 Travel (black) 4 Arm, DUMPING 10 Steering (red) 5 Bucket, DIGGING 6 Bucket, DUMPING Lever Control Hydraulic Pressure In NEUTRAL 0{0} At full stroke Nearly equal to control original pressure (see standard value table)