Komatsu — RELEASE OF REMAINING PRESSURE IN HYDRAULIC CIRCUIT

TESTING AND ADJUSTING RELEASE OF REMAINING PRESSURE IN HYDRAULIC CIRCUIT RELEASE OF REMAINING PRESSURE IN HYDRAULIC CIRCUIT 3. Inspection of boom lock valve 1) Set the work equipment at the maximum reach and the boom top horizontal. Then stop the engine. k If the piping between the hydraulic cylinders or the hydraulic motor and control valves is to be disconnected, release the remaining pressure in the following manner. There is no pressure remaining in the swing mo- tor circuit and travel motor circuit, but the internal pressure in the hydraulic tank affects them. So open the oil filler cap of the hydraulic tank.

k Lock the work equipment control levers and release the pressure inside the hydraulic tank. k Do not allow anyone to come under the work equipment during the work. 2) Disconnect drain hose (1) of the control valve, and install a blind plug in the hose. Part No. for the blind hose: 07376-70210 Leave the control valve end open. If any oil leaks out from the port that is left open, following hydraulic drift of the work equipment, the boom lock valve is defective (loose contact). 1. Stop the engine, and loosen the oil filler cap gradually to release the pressure inside the tank. 2. Turn the engine starting switch to the ON posi- tion and operate the control levers several times.

There must be power supply to the PPC lock valve. Be sure to operate the control levers with the engine starting switch in the ON po- sition. When the levers are operated 2-3 times, the pressure stored in the accumulator is re- moved. 3. Start the engine, run at low idling for approx. 10 seconds to accumulate pressure in the accumu- lator, then stop the engine. 4. Repeat the steps in Item 2 to 3 above several times. 4. Inspection of PPC valve Measure the amount of hydraulic drift of the work equipment when the accumulator is charged with pressure and the safety lock lever is put to the LOCK and FREE positions. Operate the control lever with the engine starting switch in the ON position.

If pressure in the accumulator has dropped, run the engine for approx. 10 seconds to charge the accumulator again. If there is any difference in the hydraulic drift between LOCK and FREE positions, the PPC valve is defective (some internal fail- ure). PC210/240-7K 20-141