TESTING AND ADJUSTING PREPARATIONS FOR TROUBLESHOOTING ELECTRICAL SYSTEM Good / No good Left PC210/240-7K 20-179 Inspected by: 1. Engine (PC240LC, 240NLC-7) Judgement Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good 2. Work equipment speed (PC240LC, 240NLC-7) Hydraulic oil temperature (45 55oC) – Judgement Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Good / No good Measured value Measured value Implemented on:

Standard value Failure judgement — 0.25{2.6} — 0.09{2.9} — 5.1{520} — Standard value PC240NLC-7 Failure judgement Max. 4.9 Max. 3.5 Max. 4.5 — — Max. 3.3 Max. 31 52.8 – 68.6 38.6 – 51.2 New machine 2,130 – 2,270 0.39 – 0.64{4.0 – 6.5} 980 – 1,080 Min. 0.15{Min. 1.5} 1,850 – 2,050 Max. 1.2{Max. 123} 1,300 – 1,500 New model 3.1 – 3.9 2.7 – 3.3 3.4 – 4.2 — — 2.6 – 3.2 23.3 – 28.5 52.8 – 64.6 38.6 – 47.2 Client user's name Unit rpm MPa{kg/cm2} rpm MPa{kg/cm2} rpm kPa{mmHO} 2 rpm PC240LC-7 Failure judgement Max. 4.9 Max. 3.5 Max. 4.5 — — Max. 3.3 Max.

31 48.7 – 63.6 35.6 – 47.6 Service meter reading Measurement item Engine rotation Engine oil pressure Engine rotation Engine oil pressure Engine rotation Blow-by pressure Engine rotation New model 3.1 – 3.9 2.7 – 3.3 3.4 – 4.2 — — 2.6 – 3.2 23.3 – 28.5 48.7 – 59.6 35.6 – 43.6 Condition setting Work equipment operation Operating travel control lever (Do not travel machine) All control levers in NEUTRAL Arm (extended) relief All control levers in NEUTRAL Unit Measurement item Boom RAISE Arm DUMPING Arm DIGGING Bucket DIGGING Right Left Right Left Right Left Right Serial No. Swing (5 turns) Lo ( Mi) One-touch po- wer max.

switch OFF ON OFF Condition setting Work equipment posture No load, fully extended Boom held level Boom and arm held level Fully extended Auto decelerator OFF ON Model Working mode A Working mode A E ( L) Fuel dial Full Low Full Fuel dial No. 1 2 3 4 5 6 7 No. 1 2 3 4 5 6 7 : The "Mi" and "L" modes are on the multi-monitor specification machine only. 3. Work equipment hydraulic drift amount (PC240LC, 240NLC-7) Hydraulic oil temperature (45 55oC) – Judgement Good / No good Measured value Standard value PC240NLC-7 Failure judgement Max. 900 New model 600 PC240LC-7 Failure judgement Max.

900 New model 600 Unit mm Measurement item Hydraulic drift amount at bucket tooth tip (15 min.) Condition setting Work equipment posture Boom and arm held level, Bucket loaded Working mode Engine stop Fuel dial No. 1