TESTING AND ADJUSTING INFORMATION CONTAINED IN TROUBLESHOOTING TABLE INFORMATION CONTAINED IN TROUBLESHOOTING TABLE The troubleshooting table and the related circuit diagrams contain the following information. Grasp their con- tents fully before proceeding to actual troubleshooting work.
20-304 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Title of failure phenomenon shown in failure history Display in monitor panel Display in monitor panel Display in monitor panel Failure content Failure status as detected by monitor panel or controller Response from monitor panel or controller Action taken by the monitor panel or controller to protect an affected system or equipment, when they detect some failure.
Phenomenon occurring on machine Phenomenon that occurs on the machine, resulting from the above action taken by the monitor panel or controller Relative information Information on the failure occurred as well as the troubleshooting Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Cause that presumably triggered failure in ques- tion (The assigned No. is for filing purpose only.
It does not stand for any priority) • Standard value in normalcy by which to pass "Good" or "No good" judgement over the presumed cause • Reference for passing the above "Good" or "No Good" judgement • Disconnection There is a faulty contact at the connector or disconnection of wiring harness occurred. • Defective grounding A wiring harness that is not connected with a grounding circuit has a contact with the grounding circuit. • Short-circuiting A wiring harness that is not connected with a 24 V electric circuit has a contact with the electric circuit. 1) Connector No.
display method and handling of T-adapter Insert or connect T-adapters in the following manner before starting troubleshooting unless otherwise instructed. • If there is no indication of "male" or "female" in a specific connector No., disconnect the connector and insert the T-adapter into both male and female sides. • If there is an indication of "male" or "female" in a specific connector No., disconnect the connector and connect the T-adepter with only one side of either "male" or "fe- male". 2) Entry sequence of pin No. and handling of circuit tester lead Connect the positive (+) lead and the negative (–) lead OFF a circuit tester in the fol- lowing manner unless otherwise instructed.
• Connect the positive (+) lead with the pin No. indicated at the front or the wiring har- ness. • Connect the negative (–) lead with the pin No. indicated at the front or the wiring har- ness. 2 3 4 5