Komatsu — Service Code in Electrical System (Short-circuiting in window washer drive system)

TESTING AND ADJUSTING E114 Service Code in Electrical System (Short-circuiting in window washer drive system) E114 20-312 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in window washer drive system (in Monitor Panel system) — E114 DY2CKB Failure content • Abnormal current flew to the window washer drive circuit, when the circuit was grounded and power was switched ON. Response from Monitor Panel • Power supply to the grounding in the window washer motor circuit was switched OFF. Phenomenon occurring on machine • The window washer stopped moving.

Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Window washer drive motor defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position for the troubleshooting. A50 (male) Resistance value Between and 5 – 20 Ω 2 Short-circuiting of wiring harness (Contact with 24 V circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position for the troubleshooting.

Between wiring harness from P01 (female) to J04 to A50 (female) and grounding, or between wiring har- ness between P01 (female) and D04 (female) and grounding Voltage Below 1 V 3 Monitor panel defective ★Turn the engine starting switch OFF for the preparations, and hold it in the ON position for the troubleshooting. P01 Window washer switch Voltage Between and grounding OFF 20 – 30 V ON Below 1 V