Komatsu — Service Code in Electrical System (Short-circuiting in travel interlocking solenoid)

TESTING AND ADJUSTING E201 Service Code in Electrical System (Short-circuiting in travel interlocking solenoid) E201 20-318 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in travel interlocking solenoid (in governor • pump controller system) — E201 DW91KB Failure content • Abnormal current flew to the travel interlocking circuit, when power was supplied to the circuit. Response from controller • Power supply to the travel interlocking circuit is switched OFF. • Even if the failure cause disappears of itself, the solenoid circuit does not return to normalcy, unless the engine starting switch is once turned OFF.

Phenomenon occurring on machine • It is difficult to steer the machine at turns. Relative information • Operation of the travel interlocking solenoid (ON or OFF) can be checked in the monitoring function. (Code No. 023: Solenoid) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Travel interlocking sole- noid defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

V02 (male) Resistance value Between and 20 – 60 Ω Between and grounding Above 1 MΩ 2 Assembled-type diode D03 defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. D03 (male) Resistance value Between and Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Between wiring harness from C03 (female) to J06 to V02 (female) and grounding, or between wiring har- ness between C03 (female) and D03 (female) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it running during the troubleshooting. C03 Travel control lever Voltage Between and grounding Straight forward Below 1 V Steering 20 – 30 V