TESTING AND ADJUSTING E203 Service Code in Electrical System (Short-circuiting in swing and parking brake solenoid - in governor • pump controller system) E203 20-320 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in swing and parking brake solenoid (in governor • pump controller system) E03 E203 DW45KB Failure content • Abnormal current flew to the swing and parking brake solenoid circuit, when power was supplied to the circuit. Response from controller • Power supply to the swing and parking brake solenoid circuit is switched OFF.
• Even after the failure cause disappears of itself, the swing and steering brake does not return to normal- cy, unless the engine starting switch is once turned OFF. Phenomenon occurring on machine • The upper structure cannot swing. Relative information • Operation of the swing and parking brake solenoid (ON or OFF) can be checked in the monitoring func- tion. (Code No. 023: Solenoid 1) • If there is no abnormality with the solenoid or wiring harness, the upper structure can swing by turning the emergency swing brake releasing switch to the FREE position.
(In this case, however, the parking brake does not work, when stopping the machine) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Swing and parking brake solenoid defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. V05 (male) Resistance value Between and 20 – 60 Ω Between and grounding Above 1 MΩ 2 Assembled-type diode D03 defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.
D03 (male) Resistance value Between and Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. Wiring harness from C03 (female) to D01 to J02 to X05 to J06 to V05 (female) , or between wiring harness between C03 (female) and D03 (female) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it running during the troubleshooting. C03 Swing control lever Voltage Between and grounding NEUTRAL Below 1 V Swing 20 – 30 V