Komatsu — Service Code in Electrical System (Short-circuiting in merge/divide solenoid)

TESTING AND ADJUSTING E204 Service Code in Electrical System (Short-circuiting in merge/divide solenoid) E204 20-322 PC210/240-7K User Code Service Code Failure Code Failure phenomenon Short-circuiting in merge/divide solenoid (in governor • pump controller system) — E204 DWJ0KB Failure content • Abnormal current flew to the merge/divide solenoid circuit, when power was supplied to the circuit. Response from controller • Power supply to the merge/divide solenoid circuit is switched OFF. • Even after the failure cause disappears of itself, the machine operation does not return to normalcy, un- less the engine starting switch is once turned OFF.

Phenomenon occurring on machine • In L mode, the work equipment moves slowly, or the swing speed is slow in its single operation. Relative information • Operation of the merge/divide solenoid (ON or OFF) can be checked in the monitoring function. (Code No. 023: Solenoid 1) Presumed cause and standard value in normalcy Cause Standard value in normalcy and references for troubleshooting 1 Merge/divide solenoid defective (Internal short-circuiting or grounding fault) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

V03 (male) Resistance value Between and 20 – 60 Ω Between and grounding Above 1 MΩ 2 Assembled-type diode D03 defective (Internal short-circuiting) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting. D03 (male) Resistance value Between and Above 1 MΩ 3 Grounding fault of wiring harness (Contact with grounding circuit) ★Turn the engine starting switch OFF for the preparations, and hold it in the OFF position during the troubleshooting.

Wiring harness from C03 (female) to J06 to V03 (female) , or between wiring harness between C03 (female) and D03 (female) and grounding Resistance value Above 1 MΩ 4 Governor • pump controller defective ★Turn the engine starting switch OFF for the preparations, and hold it running during the troubleshooting. C03 Travel control lever Voltage Between and grounding NEUTRAL Below 1 V When operating one side only 20 – 30 V